5.3 - Thermodynamics
- Syllabus
- 2021
- Topic
- 5.3
- Level
- A2
ΔE=mcΔθandΔE=LΔm
| Process | Relationship | Quantity meaning |
|---|---|---|
| temperature changes without a phase change | ΔE=mcΔθ | c is specific heat capacity in Jkg−1K−1 |
| mass changes phase at constant transition temperature | ΔE=LΔm | L is specific latent heat in Jkg−1 |
To warm 0.40kg of ice with c=2100Jkg−1K−1 through 15K requires 12.6kJ. Melting that mass then requires a separate LΔm calculation. Add energies for successive stages; do not combine their equations into one substitution.
A Celsius temperature change has the same numerical size as a kelvin change, but an absolute temperature does not. During an ideal phase change the supplied energy changes molecular potential energy rather than temperature; account for power and time with E=Pt and state when heat losses make this an approximation.
Place an NTC thermistor and fixed resistor in series across a stable d.c. supply. Measure the potential-divider output across the chosen component with a voltmeter, while the thermistor and a calibrated thermometer or temperature probe sit close together in a stirred water bath.
| Stage | Action |
|---|---|
| span the range | begin with an ice-water mixture near 0 C, then warm the bath in small intervals |
| equilibrate | stir gently and wait until temperature and output voltage are steady |
| record | take repeated paired readings of temperature and divider output |
| calibrate | plot output voltage against temperature and interpolate the voltage for the thermostat set point |
An NTC thermistor's resistance falls as temperature rises. If output is measured across the thermistor, Vout=VsRT/(RT+R) falls; measured across the fixed resistor, it rises. A comparator or relay can switch heating when the calibrated threshold is crossed.
Calibration belongs to the actual circuit orientation and supply voltage. Do not infer temperature from a generic resistance value, take readings while the sensor is still warming, or place the reference thermometer far from the thermistor; these choices create systematic disagreement.
For latent heat of vaporisation, use an immersion heater to keep a liquid boiling steadily. Measure heater voltage and current, and use a balance to determine the mass lost during a timed interval after steady boiling has begun. A lid or insulation reduces energy transfer to the surroundings without sealing the vessel.
L=ΔmE=ΔmVIΔt
| Control or measurement | Why it matters |
|---|---|
| use steady boiling before timing | energy is then mainly associated with the phase change |
| record mass before and after the same interval | gives vaporised mass Δm |
| repeat for several intervals or powers | checks consistency and supports a gradient method |
| keep heater immersed and observe electrical safety | maintains energy transfer and prevents damage |
If all electrical input is treated as latent energy, transfer to the surroundings usually makes the calculated L too large. Underestimating heater power makes it too small. Do not include the initial warming period, and never seal a boiling container because pressure can rise.
A substance's internal energy is the total randomly distributed kinetic energy and intermolecular potential energy of its molecules. Random molecular motion contributes kinetic energy; relative molecular positions and interactions contribute potential energy.
| Process | Molecular kinetic energy | Molecular potential energy |
|---|---|---|
| cooling within one phase | decreases as temperature falls | may change, but not the main simple-model change |
| freezing at constant temperature | average kinetic energy stays constant | decreases as molecules form a more strongly bound arrangement |
| melting at constant temperature | average kinetic energy stays constant | increases as molecular separation/arrangement changes |
On a cooling curve, a sloping section shows falling temperature and therefore falling average molecular kinetic energy. A constant-temperature phase-change section can still show decreasing internal energy because molecular potential energy decreases.
Internal energy excludes the kinetic energy of the whole sample moving through the laboratory and its gravitational potential energy as a whole. Constant temperature does not always mean constant internal energy when a phase change is occurring.
For an ideal gas, the average translational kinetic energy of its molecules is directly proportional to absolute temperature: ⟨Ek⟩∝T. Equal absolute temperatures therefore mean equal average translational kinetic energy, even for gases with different molecular masses.
The kelvin scale starts at absolute zero: 0K=−273.15∘C. Convert with T/K=θ/∘C+273.15. A rise of 1K is the same size as a rise of 1∘C, but the scale origins differ.
When temperature rises, molecules have greater mean-square speed and momentum, so wall collisions transfer momentum more frequently or more strongly. This microscopic change explains increases in gas pressure or volume under the relevant macroscopic constraint.
Proportionality uses kelvin, not degrees Celsius. At absolute zero the classical ideal-gas model extrapolates average translational kinetic energy to zero; absolute zero is not minus 273 K and cannot be reached simply by subtracting a Celsius value.
pV=NkT
Use pressure p in pascals, volume V in cubic metres, absolute temperature T in kelvin, number of molecules N, and Boltzmann constant k=1.38×10−23JK−1. The equation models an ideal gas in equilibrium.
For N=5.0×1022 molecules at 300K occupying 1.8×10−3m3, p=NkT/V=1.15×105Pa. Convert litres to cubic metres and use the number of molecules, not the number of moles.
| Fixed quantity | Consequence from pV=NkT |
|---|---|
| N,T | pV is constant |
| N,V | p is proportional to T |
| N,p | V is proportional to T |
Temperature must be absolute and pressure must be absolute, not gauge pressure. Real gases approach ideal behaviour most closely at low density; do not use a changing N relationship as though the gas sample were sealed.
Trap a fixed mass of gas in a sealed syringe or Boyle's-law apparatus connected to an absolute pressure sensor. Change the volume in measured steps, secure the piston, and wait for the pressure to stabilise before recording each pair.
| Role | Quantity and control |
|---|---|
| independent | gas volume V, including any fixed connecting-tube dead volume |
| dependent | absolute gas pressure p |
| controlled | gas amount and temperature; compress slowly and allow thermal equilibrium |
| safety | do not exceed apparatus pressure rating; secure connections and eye protection |
Repeat readings across the safe range. Either calculate pV for several pairs and look for a constant value, or plot p against 1/V: a straight line through the origin supports p∝1/V at fixed temperature.
Rapid compression warms the gas and breaks the fixed-temperature condition. Gauge pressure must be converted to absolute pressure, and uncounted tubing volume shifts the relationship; a curved p-against-V graph alone is not sufficient proof of inverse proportionality.
Kinetic theory gives pV=31Nm⟨c2⟩, where m is one molecule's mass and ⟨c2⟩ is the mean square speed. The ideal gas equation gives pV=NkT. Equating them and cancelling N produces the required molecular-energy relation.
21m⟨c2⟩=23kT
The left side is the average translational kinetic energy per molecule. It can also be written as 3pV/(2N). For p=1.15×105Pa, V=1.77×10−3m3 and N=5.15×1022, the average is 5.93×10−21J.
The symbol ⟨c2⟩ means the average of squared molecular speeds, not the square of the average velocity, which is zero for random motion. Use the mass of one molecule, and do not insert the total gas mass into the per-molecule equation.